Keysight Ixia Vision Product Family

1 month 1 week ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 8.6
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Keysight
  • Equipment: Ixia Vision Product Family
  • Vulnerabilities: Path Traversal, Improper Restriction of XML External Entity Reference
2. RISK EVALUATION

Successful exploitation of these vulnerabilities could crash the device being accessed; a buffer overflow condition may allow remote code execution.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

Keysight reports the following versions of Vision Network Packet Broker product family are affected:

  • Ixia Vision Product Family: Versions 6.3.1
3.2 VULNERABILITY OVERVIEW 3.2.1 Improper Limitation of a Pathname to a Restricted Directory CWE-22

Path traversal may allow remote code execution using privileged account (requires device admin account, cannot be performed by a regular user). In combination with the 'Upload' functionality this could be used to execute an arbitrary script or possibly an uploaded binary. Remediation in Version 6.7.0, release date: 20-Oct-24.

CVE-2025-24494 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.2 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-24494. A base score of 8.6 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.2 Improper Restriction of XML External Entity Reference CWE-611

External XML entity injection allows arbitrary download of files. The score without least privilege principle violation is as calculated below. In combination with other issues it may facilitate further compromise of the device. Remediation in Version 6.8.0, release date: 01-Mar-25.

CVE-2025-24521 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.9 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2025-24521 . A base score of 6.9 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.2.3 Improper Limitation of a Pathname to a Restricted Directory CWE-22

Path traversal may lead to arbitrary file download. The score without least privilege principle violation is as calculated below. In combination with other issues it may facilitate further compromise of the device. Remediation in Version 6.8.0, release date: 01-Mar-25.

CVE-2025-21095 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.9 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2025-21095. A base score of 6.9 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.2.4 Improper Limitation of a Pathname to a Restricted Directory CWE-22

Path traversal may lead to arbitrary file deletion. The score without least privilege principle violation is as calculated below. In combination with other issues it may facilitate further compromise of the device. Remediation in Version 6.8.0, release date: 01-Mar-25.

CVE-2025-23416 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.9 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N).

A CVSS v4 score has also been calculated for CVE-2025-23416. A base score of 6.9 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Information Technology
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER

NATO Cyber Security Centre (NCSC) reported these vulnerabilities to Keysight.

4. MITIGATIONS

Keysight recommends that all users upgrade to the latest version of software as soon as possible. Older versions of this software may have this vulnerability; Keysight recommends that users discontinue the use of older software versions.

For more information about the Ixia Vision Product Family, please visit Ixia product support

Further questions can be answered by contacting Keysight.

CISA recommends users take defensive measures to minimize the risk of exploitation of this these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY
  • March 4, 2025: Initial Publication
CISA

Schneider Electric Communication Modules for Modicon M580 and Quantum Controllers

1 month 2 weeks ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v3 9.8
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Schneider Electric
  • Equipment: Communication modules for Modicon M580 and Quantum controllers
  • Vulnerability: Out-of-bounds Write
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow a stack overflow attack, which could result in loss of confidentiality, integrity, and denial of service of the device.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

Schneider Electric reports that the following communication modules for Modicon M580 and Quantum controllers are affected by a vulnerability in VxWorks operating system:

  • Modicon M580 communication modules BMENOC BMENOC0321: Versions prior to SV1.10
  • Modicon M580 communication modules BMECRA BMECRA31210: All versions
  • Modicon M580/Quantum communication modules BMXCRA BMXCRA31200: All versions
  • Modicon M580/Quantum communication modules BMXCRA BMXCRA31210: All versions
  • Modicon Quantum communication modules 140CRA 140CRA31908: All versions
  • Modicon Quantum communication modules 140CRA 140CRA31200: All versions
3.2 VULNERABILITY OVERVIEW 3.2.1 OUT-OF-BOUNDS WRITE CWE-787

A possible stack overflow in dhcp server was discovered in Wind River VxWorks through 6.8.

CVE-2021-29999 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Critical Manufacturing, Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: France
3.4 RESEARCHER

Schneider Electric reported this vulnerability to CISA.

4. MITIGATIONS

Schneider Electric has identified the following specific remediations and mitigations users can apply to reduce risk:

  • Modicon M580 communication modules BMENOC BMENOC0321: Version SV1.10 of BMENOC0321 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product/BMENOC0321/m580- noc-control/
  • Schneider Electric is establishing a remediation plan for all future versions of BMECRA, BMXCRA and 140CRA that will include a fix for this vulnerability. They will update SEVD-2025-014-03 when the remediation is available. Until then, users should immediately implement a firewall to allow only authorized traffic on 67/UDP and 68/UDP ports to reduce the risk of exploit.

Schneider Electric strongly recommends the following industry cybersecurity best practices.

  • Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
  • Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.
  • Place all controllers in locked cabinets and never leave them in the "Program" mode.
  • Never connect programming software to any network other than the network intended for that device.
  • Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.
  • Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.
  • Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.
  • When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.

For more information refer to the Schneider Electric Recommended Cybersecurity Best
Practices document.

For more information, see Schneider Electric security notification "SEVD-2025-014-03 Wind River VxWorks DHCP server vulnerability"

Additional information about the vulnerability can be found on the Wind River site.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY
  • February 27, 2025: Initial Publication
CISA

Rockwell Automation PowerFlex 755

1 month 2 weeks ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 8.7
  • ATTENTION: Exploitable remotely/Low attack complexity
  • Vendor: Rockwell Automation
  • Equipment: PowerFlex 755
  • Vulnerability: Cleartext Transmission of Sensitive Information
2. RISK EVALUATION

Successful exploitation of this vulnerability could result in exposure of sensitive data.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

The following version of PowerFlex 755, a motor application control drive software, is affected:

  • PowerFlex 755: Versions 16.002.279 and prior
3.2 VULNERABILITY OVERVIEW 3.2.1 CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319

The affected version of the product is vulnerable to credential exposure due to using HTTP, resulting in credentials being sent in clear text. This can allow sensitive data to be sniffed and captured by an attacker.

CVE-2025-0631 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2025-0631. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER

Rockwell Automation reported this vulnerability to CISA.

4. MITIGATIONS

Rockwell Automation has provided an updated version of PowerFlex 755 software, v20.3.407, which users are encouraged to apply. For information on how to mitigate security risks on industrial automation control systems, Rockwell Automation also encourages users to implement suggested security best practices to minimize the risk of the vulnerability.

For more information refer to Rockwell Automation's security advisory.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY

February 25, 2025: Initial Publication

CISA

ABB ASPECT-Enterprise, NEXUS, and MATRIX Series

1 month 3 weeks ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 9.3
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: ABB
  • Equipment: ASPECT-Enterprise, NEXUS, and MATRIX series
  • Vulnerability: Use of Hard-coded Credentials
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to obtain access to devices without proper authentication.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

ABB reports the following products are affected:

  • ABB ASPECT®-Enterprise ASP-ENT-x: Versions 3.08.03 and prior
  • ABB NEXUS Series NEX-2x: Versions 3.08.03 and prior
  • ABB NEXUS Series: Versions 3.08.03 and prior
  • ABB MATRIX Series MAT-x: Versions 3.08.03 and prior
3.2 VULNERABILITY OVERVIEW 3.2.1 USE OF HARD-CODED CREDENTIALS CWE-798

Several hard-coded credentials for the products internal use are contained in the firmware as plain text information.

CVE-2024-51547 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-51547. A base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Switzerland
3.4 RESEARCHER

Gjoko Krstikj of Zero Science Lab reported this vulnerability to CISA.

4. MITIGATIONS

ABB has identified specific workarounds and mitigations users can apply to reduce risk and recommends users to perform the following actions on any released SW version of ASPECT:

  • Stop and disconnect any ASPECT products that are exposed directly to the Internet, either via a direct ISP connection or via NAT port forwarding.
  • Ensure that physical controls are in place, so no unauthorized personnel can access your devices, components, peripheral equipment, and networks.
  • Ensure log-files, downloaded from the equipment is protected against unauthorized access.
  • Ensure that all ASPECT products are upgraded to the latest firmware version. Please find the latest version of ASPECT firmware on the respective product homepage.
  • When remote access is required, only use secure methods. If a Virtual Private Network (VPN) is used, ensure that the chosen VPN is secure i.e. updated to the most current version available and configured for secure access.

For more information, please refer to ABB's cybersecurity advisory 9AKK108470A6775.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY
  • February 20, 2025: Initial Publication
CISA

Siemens SiPass Integrated

1 month 3 weeks ago

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 9.3
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SiPass integrated
  • Vulnerability: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code on the application server, if a specially crafted backup set is used for a restore.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • SiPass integrated V2.90: Versions prior to V2.90.3.19
  • SiPass integrated V2.95: Versions prior to V2.95.3.15
3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER LIMITATION OF A PATHNAME TO A RESTRICTED DIRECTORY ('PATH TRAVERSAL') CWE-22

Directory traversal vulnerability in DotNetZip versions v.1.16.0 and prior which allows a remote attacker to execute arbitrary code via the src/Zip.Shared/ZipEntry.Extract.cs component. This vulnerability only affects products that are no longer supported by the maintainer. For SiPass integrated V2.90 and V2.95: The product could only be exploitable in situations where a specially crafted backup set is used for a restore.

CVE-2024-48510 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-48510. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER

Siemens ProductCERT reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has released a new version for SiPass integrated and recommends updating to the latest version:

  • SiPass integrated V2.90: Update to V2.90.3.19 or later version
  • SiPass integrated V2.95: Update to V2.95.3.15 or later version

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • Ensure that only trusted persons are permitted to initiate a restore via the Configuration Client
  • Do not use untrusted backup files for a restore

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-992434 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY
  • February 20, 2025: Initial Publication
CISA

ABB FLXEON Controllers

1 month 3 weeks ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 10.0
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: ABB
  • Equipment: FLXEON Controllers
  • Vulnerabilities: Improper Control of Filename for Include/Require Statement in PHP Program ('PHP Remote File Inclusion'), Missing Origin Validation in WebSockets, Insertion of Sensitive Information into Log File
2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to send unauthorized HTTPS requests, access sensitive information from HTTPS responses, or use network access to execute remote code.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

ABB reports that the following products are affected:

  • FLXEON Controllers FBXi: Version 9.3.4 and prior
  • FLXEON Controllers FBVi: Version 9.3.4 and prior
  • FLXEON Controllers FBTi: Version 9.3.4 and prior
  • FLXEON Controllers CBXi: Version 9.3.4 and prior
3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77

Network access can be used to execute arbitrary code with elevated privileges. This issue affects FLXEON version 9.3.4 and prior.

CVE-2024-48841 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-48841. A base score of 10.0 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H).

3.2.2 MISSING ORIGIN VALIDATION IN WEBSOCKETS CWE-1385

Session management is not sufficient to prevent unauthorized HTTPS requests. This issue affects FLXEON version 9.3.4 and prior.

CVE-2024-48849 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-48849. A base score of 8.8 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.3 INSERTION OF SENSITIVE INFORMATION INTO LOG FILE CWE-532

Some information may be improperly disclosed through HTTPS access. This issue affects FLXEON version 9.3.4 and prior.

CVE-2024-48852 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-48852. A base score of 8.8 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Switzerland
3.4 RESEARCHER

Gjoko Krstikj of Zero Science Lab reported these vulnerabilities through responsible disclosure.

4. MITIGATIONS

ABB recommends that users update to firmware version 9.3.5.

ABB recommends that users immediately do the following actions on any released version of FLXEON:

  • Stop and disconnect any FLXEON products that are exposed directly to the Internet, either via a direct ISP connection or via NAT port forwarding.
  • Ensure that physical controls are in place, so no unauthorized personnel can access your devices, components, peripheral equipment, and networks.
  • Ensure that all FLXEON products are upgraded to the latest firmware version (9.3.5 or above). Please find the latest version of FLXEON firmware on the respective product homepage.
  • When remote access is required, only use secure methods. If a virtual private network (VPN) is used, ensure that the chosen VPN is secure i.e. updated to the most current version available and configured for secure access.

For more information, please refer to ABB's cybersecurity advisory 9AKK108470A5684.

ABB states that these vulnerabilities are only exploitable if attackers can access the network segment where FLXEON is installed and exposed directly to the internet. ABB therefore recommends the following guidelines in order to protect users networks:

  • FLXEON devices should never be exposed directly to the Internet either via a direct ISP connection nor via NAT port forwarding. If remote access to a FLXEON system is a user requirement, the system shall operate behind a firewall. Users accessing FLXEON remotely shall do this using a VPN gateway allowing access to the particular network segment where FLXEON is in stalled and configured.
  • It is crucial that the VPN gateway and network are set up in accordance with best industry standards and maintained in terms of security patches for all related components.
  • Change default passwords if they are still in use.
  • Ensure that all FLXEON products are upgraded to the latest firmware version. Please find the latest version of FLXEON firmware on the respective product homepage.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY
  • February 20, 2025: Initial Publication
CISA

Rapid Response Monitoring My Security Account App

1 month 3 weeks ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 8.7
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Rapid Response Monitoring
  • Equipment: My Security Account App
  • Vulnerability: Authorization Bypass Through User-Controlled Key
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow attacker to access sensitive information of other users.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

The following Rapid Response Monitoring products are affected:

  • My Security Account App API: Versions prior to 7/29/24
3.2 VULNERABILITY OVERVIEW 3.2.1 Authorization Bypass Through User-Controlled Key CWE-639

Rapid Response Monitoring My Security Account App utilizes an API that could be exploited by an attacker to modify request data, potentially causing the API to return information about other users.

CVE-2025-0352 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2025-0352. A base score of 8.7 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Emergency Services
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER

kbots reported this vulnerability to CISA.

4. MITIGATIONS

Rapid Response Monitoring reports that this issue was patched on their end and no action is required by users. For further information, contact Rapid Response Monitoring.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY
  • February 20, 2025: Initial Publication
CISA

Carrier Block Load

1 month 3 weeks ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 7.1
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Carrier
  • Equipment: Block Load
  • Vulnerability: Uncontrolled Search Path Element
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow a malicious actor to execute arbitrary code with escalated privileges .

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

The following Carrier product, which is a HVAC load calculation program, are affected:

  • Block Load: Version 4.16
3.2 VULNERABILITY OVERVIEW 3.2.1 UNCONTROLLED SEARCH PATH ELEMENT CWE-427

The vulnerability could allow a malicious actor to perform DLL hijacking and execute arbitrary code with escalated privileges.

CVE-2024-10930 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-10930. A base score of 7.1 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities
  • COUNTRIES/AREAS DEPLOYED: United States
  • COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER

An anonymous researcher reported this vulnerability to Carrier.

4. MITIGATIONS

Carrier recommends users to upgrade the product to v4.2 or later. If any issues arise, users are encouraged to contact Carrier directly. For more information refer to Carrier's security advisory.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY
  • February 20, 2025: Initial Publication
CISA

Elseta Vinci Protocol Analyzer

1 month 3 weeks ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 9.4
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Elseta
  • Equipment: Vinci Protocol Analyzer
  • Vulnerability: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to escalate privileges and perform code execution on the affected system.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

The following Elseta products are affected:

Vinci Protocol Analyzer: Versions prior to 3.2.3.19

3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN OS COMMAND ('OS COMMAND INJECTION') CWE-78

An OS command injection vulnerability exists in Vinci Protocol Analyzer that could allow an attacker to escalate privileges and perform code execution on affected system.

CVE-2025-1265 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-1265. A base score of 9.4 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing, Communications
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Lithuania
3.4 RESEARCHER

Nguyen Huu Thien Duc reported this vulnerability to CISA.

4. MITIGATIONS

Elseta recommends affected users update to version 3.2.3.19 or later. Contact Elseta for more information.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY
  • February 20, 2025: Initial Publication
CISA

Siemens OpenV2G

2 months ago

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v3 6.2
  • ATTENTION: Low attack complexity
  • Vendor: Siemens
  • Equipment: OpenV2G
  • Vulnerability: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to trigger memory corruption.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • Siemens OpenV2G: All versions prior to V0.9.6
3.2 VULNERABILITY OVERVIEW 3.2.1 BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-120

The OpenV2G EXI parsing feature is missing a length check when parsing X509 serial numbers. Thus, an attacker could introduce a buffer overflow that leads to memory corruption.

CVE-2025-24956 has been assigned to this vulnerability. A CVSS v3 base score of 6.2 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER

Qianyi Zhang from Bosch GS Cybersecurity Lab reported this vulnerability to Siemens.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-647005 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY
  • February 13, 2025: Initial Publication
CISA

Siemens RUGGEDCOM APE1808 Devices

2 months ago

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v3 7.5
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: RUGGEDCOM APE1808 Devices
  • Vulnerabilities: Out-of-bounds Read, Insertion of Sensitive Information Into Sent Data, Allocation of Resources Without Limits or Throttling, Integer Overflow or Wraparound, Path Traversal, Out-of-bounds Write, HTTP Request/Response Splitting
2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of service condition, perform a machine-in-the middle attack (MITM), escalate privileges, execute unauthorized code, and access unauthorized systems and information.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • Siemens RUGGEDCOM APE1808: All versions
3.2 VULNERABILITY OVERVIEW 3.2.1 OUT-OF-BOUNDS READ CWE-125

An out-of-bounds read vulnerability [CWE-125] in FortiOS SSLVPN web portal versions 7.4.0 through 7.4.4, versions 7.2.0 through 7.2.8, 7.0 all versions, and 6.4 all versions may allow an authenticated attacker to perform a denial-of-service on the SSLVPN web portal via a specially crafted URL.

CVE-2024-36504 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.2 INSERTION OF SENSITIVE INFORMATION INTO SENT DATA CWE-201

An insertion of sensitive information into sent data vulnerability [CWE-201] in FortiOS 7.6.0, 7.4.0 through 7.4.4 may allow an attacker in a man-in-the-middle position to retrieve the RADIUS accounting server shared secret via intercepting accounting-requests.

CVE-2024-46665 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N).

3.2.3 ALLOCATION OF RESOURCES WITHOUT LIMITS OR THROTTLING CWE-770

An allocation of resources without limits or throttling [CWE-770] vulnerability in FortiOS versions 7.6.0, versions 7.4.4 through 7.4.0, 7.2 all versions, 7.0 all versions, 6.4 all versions may allow a remote unauthenticated attacker to prevent access to the GUI via specially crafted requests directed at specific endpoints.

CVE-2024-46666 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.2.4 ALLOCATION OF RESOURCES WITHOUT LIMITS OR THROTTLING CWE-770

An allocation of resources without limits or throttling vulnerability [CWE-770] in FortiOS versions 7.4.0 through 7.4.4, versions 7.2.0 through 7.2.8, versions 7.0.0 through 7.0.15, and versions 6.4.0 through 6.4.15 may allow an unauthenticated remote user to consume all system memory via multiple large file uploads.

CVE-2024-46668 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.5 INTEGER OVERFLOW OR WRAPAROUND CWE-190

An Integer Overflow or Wraparound vulnerability in version 7.4.4 and below, version 7.2.10 and below; FortiSASE version 23.4.b FortiOS tenant IPsec IKE service may allow an authenticated attacker to crash the IPsec tunnel via crafted requests, resulting in potential denial-of-service.

CVE-2024-46669 has been assigned to this vulnerability. A CVSS v3 base score of 3.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L).

3.2.6 OUT-OF-BOUNDS READ CWE-125

An Out-of-bounds Read vulnerability in FortiOS version 7.6.0, version 7.4.4 and below, version 7.2.9 and below and FortiSASE FortiOS tenant version 24.3.b IPsec IKE service may allow an unauthenticated remote attacker to trigger memory consumption leading to denial-of-service via crafted requests.

CVE-2024-46670 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.7 IMPROPER LIMITATION OF A PATHNAME TO A RESTRICTED DIRECTORY ('PATH TRAVERSAL') CWE-22

A improper limitation of a pathname to a restricted directory ('path traversal') in Fortinet FortiManager versions 7.6.0 through 7.6.1, 7.4.1 through 7.4.3, FortiOS versions 7.6.0, 7.4.0 through 7.4.4, 7.2.5 through 7.2.9, 7.0.0 through 7.0.15, 6.4.0 through 6.4.15, FortiProxy 7.4.0 through 7.4.5, 7.2.0 through 7.2.11, 7.0.0 through 7.0.18, 2.0.0 through 2.0.14, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7, FortiManager Cloud versions 7.4.1 through 7.4.3 allows attacker to trigger an escalation of privilege via specially crafted packets.

CVE-2024-48884 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.8 IMPROPER LIMITATION OF A PATHNAME TO A RESTRICTED DIRECTORY ('PATH TRAVERSAL') CWE-22

A improper limitation of a pathname to a restricted directory ('path traversal') in Fortinet FortiRecorder versions 7.2.0 through 7.2.1, 7.0.0 through 7.0.4, FortiWeb versions 7.6.0, 7.4.0 through 7.4.4, 7.2.0 through 7.2.10, 7.0.0 through 7.0.10, 6.4.0 through 6.4.3, FortiVoice versions 7.0.0 through 7.0.4, 6.4.0 through 6.4.9, 6.0.0 through 6.0.12 allows attacker to escalate privilege via specially crafted packets.

CVE-2024-48885 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.9 OUT-OF-BOUNDS WRITE CWE-787

A out-of-bounds write in Fortinet FortiOS versions 7.6.0, 7.4.0 through 7.4.6, 7.2.0 through 7.2.10, 7.0.0 through 7.0.16, 6.4.0 through 6.4.15 allows attacker to trigger a denial-of-service via specially crafted packets.

CVE-2024-52963 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.2.10 IMPROPER NEUTRALIZATION OF CRLF SEQUENCES IN HTTP HEADERS ('HTTP REQUEST/RESPONSE SPLITTING') CWE-113

An improper neutralization of crlf sequences in http headers ('http response splitting') in Fortinet FortiOS 7.2.0 through 7.6.0, FortiProxy 7.2.0 through 7.4.5 allows attacker to execute unauthorized code or commands via crafted HTTP header.

CVE-2024-54021 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • RUGGEDCOM APE1808: Contact customer support to receive patch and update information.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-770770 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY
  • February 13, 2025: Initial Publication
CISA

Siemens Questa and ModelSim

2 months ago

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v3 6.7
  • ATTENTION: High attack complexity
  • Vendor: Siemens
  • Equipment: Questa, ModelSim
  • Vulnerability: Uncontrolled Search Path Element
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow a local attacker to inject arbitrary code and escalate privileges.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • Siemens Questa: All versions prior to V2025.1
  • Siemens ModelSim: All versions prior to V2025.1
3.2 VULNERABILITY OVERVIEW 3.2.1 UNCONTROLLED SEARCH PATH ELEMENT CWE-427

An example setup script contained in affected applications allows a specific executable file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch the script from a user-writable directory.

CVE-2024-53977 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER

Siemens reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • All affected products: Update to V2025.1 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-637914 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. This vulnerability has a high attack complexity.

5. UPDATE HISTORY
  • February 13, 2025: Initial Publication

 

CISA

Siemens APOGEE PXC and TALON TC Series

2 months ago

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 8.7
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: APOGEE PXC and TALON TC Series
  • Vulnerabilities: Inadequate Encryption Strength, Out-of-bounds Read
2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to perform a denial of service using a out-of-bounds read forcing the device to enter a cold state and a vulnerability that would allow an attacker to decrypt the passwords of the device.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • APOGEE PXC Series (P2 Ethernet): All versions
  • APOGEE PXC Series (BACnet): All versions
  • TALON TC Series (BACnet): All versions
3.2 VULNERABILITY OVERVIEW 3.2.1 INADEQUATE ENCRYPTION STRENGTH CWE-326

Affected devices contain a weak encryption mechanism with a hard-coded key allowing an attacker to guess or reverse engineer the password from the cyphertext.

CVE-2024-54089 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2024-54089. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.2.2 OUT-OF-BOUNDS READ CWE-125

An authenticated user with a Medium(MED) account could connect to the device and perform an out-of-bound read using memory dump functionality. An attacker could use this to cause the device to enter an insecure cold start state.

CVE-2024-54090 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2024-54090. A base score of 6.0 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

For CVE-2024-54089:

  • Use strong, hard to guess passwords

For CVE-2024-54090:

  • Ensure all three default passwords are changed even if not in use.
  • Disable telnet (Telnet is disabled by default).

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-615116 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY
  • February 13, 2025: Initial Publication
CISA

Siemens SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor

2 months ago

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 7.3
  • ATTENTION: Exploitable locally
  • Vendor: Siemens
  • Equipment: SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor
  • Vulnerability: Incorrect Permission Assignment for Critical Resource
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an authenticated attacker to achieve privilege escalation or bypass security measures.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • SMATIC IPC DiagMonitor: All versions
  • SIMATIC IPC DiagBase: All versions
3.2 VULNERABILITY OVERVIEW 3.2.1 INCORRECT PERMISSION ASSIGNMENT FOR CRITICAL RESOURCE CWE-732

The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to privilege escalation or bypassing endpoint protection and other security measures.

CVE-2025-23403 has been assigned to this vulnerability. A CVSS v3 base score of 7.0 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-23403. A base score of 7.3 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER

Siemens reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-369369 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. This vulnerability has a high attack complexity.

5. UPDATE HISTORY
  • February 13, 2025: Initial Publication
CISA

Siemens SIPROTEC 5

2 months ago

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 7.0
  • ATTENTION: Low attack complexity
  • Vendor: Siemens
  • Equipment: SIPROTEC 5
  • Vulnerability: Active Debug Code
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an unauthenticated attacker with physical access to an affected device to execute arbitrary commands on the device.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • Siemens SIPROTEC 5 7SK85 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SJ81 (CP100): All versions
  • Siemens SIPROTEC 5 7SL86 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SL86 (CP200): All versions
  • Siemens SIPROTEC 5 7SJ86 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SK82 (CP100): All versions
  • Siemens SIPROTEC 5 6MD84 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SA87 (CP200): All versions
  • Siemens SIPROTEC 5 7ST85 (CP300): All versions
  • Siemens SIPROTEC 5 7SD87 (CP200): All versions
  • Siemens SIPROTEC 5 7UT87 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 6MD89 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SD82 (CP100): All versions
  • Siemens SIPROTEC 5 6MD85 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7ST86 (CP300): All versions
  • Siemens SIPROTEC 5 7SJ82 (CP150): All versions prior to V9.90
  • Siemens SIPROTEC 5 7UT86 (CP200): All versions
  • Siemens SIPROTEC 5 7SX85 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SD87 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7VU85 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 6MU85 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SD86 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7UT86 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7VK87 (CP200): All versions
  • Siemens SIPROTEC 5 7UT85 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7UT82 (CP150): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SA87 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SJ81 (CP150): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SJ82 (CP100): All versions
  • Siemens SIPROTEC 5 7SA82 (CP100): All versions
  • Siemens SIPROTEC 5 7UT87 (CP200): All versions
  • Siemens SIPROTEC 5 7SX82 (CP150): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SD86 (CP200): All versions
  • Siemens SIPROTEC 5 7SL87 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 6MD85 (CP200): All versions
  • Siemens SIPROTEC 5 7ST85 (CP200): All versions
  • Siemens SIPROTEC 5 Compact 7SX800 (CP050): All versions prior to V9.90
  • Siemens SIPROTEC 5 6MD86 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SD82 (CP150): All versions prior to V9.90
  • Siemens SIPROTEC 5 7KE85 (CP300): All versions
  • Siemens SIPROTEC 5 7SL82 (CP100): All versions
  • Siemens SIPROTEC 5 7SL82 (CP150): All versions prior to V9.90
  • Siemens SIPROTEC 5 7VE85 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7KE85 (CP200): All versions
  • Siemens SIPROTEC 5 7SA86 (CP200): All versions
  • Siemens SIPROTEC 5 7SL87 (CP200): All versions
  • Siemens SIPROTEC 5 7SY82 (CP150): All versions prior to V9.90
  • Siemens SIPROTEC 5 6MD86 (CP200): All versions
  • Siemens SIPROTEC 5 7SJ86 (CP200): All versions
  • Siemens SIPROTEC 5 7SA86 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7UM85 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SS85 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SK82 (CP150): All versions prior to V9.90
  • Siemens SIPROTEC 5 7UT82 (CP100): All versions
  • Siemens SIPROTEC 5 7SS85 (CP200): All versions
  • Siemens SIPROTEC 5 7SJ85 (CP200): All versions
  • Siemens SIPROTEC 5 7UT85 (CP200): All versions
  • Siemens SIPROTEC 5 7SK85 (CP200): All versions
  • Siemens SIPROTEC 5 7VK87 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SJ85 (CP300): All versions prior to V9.90
  • Siemens SIPROTEC 5 7SA82 (CP150): All versions prior to V9.90
3.2 VULNERABILITY OVERVIEW 3.2.1 ACTIVE DEBUG CODE CWE-489

Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device.

CVE-2024-53648 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-53648. A base score of 7.0 has been calculated; the CVSS vector string is (CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER

Steffen Robertz, Stefan Viehböck, and Constantin Schieber-Knöbl from SEC Consult Vulnerability Lab reported this vulnerability to Siemens.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • All affected products: Restrict physical access to authorized individuals only to limit exposure
  • SIPROTEC 5 6MD85 (CP200), SIPROTEC 5 6MD86 (CP200), SIPROTEC 5 7KE85 (CP200), SIPROTEC 5 7SA86 (CP200), SIPROTEC 5 7SA87 (CP200), SIPROTEC 5 7SD86 (CP200), SIPROTEC 5 7SD87 (CP200), SIPROTEC 5 7SJ85 (CP200), SIPROTEC 5 7SJ86 (CP200), SIPROTEC 5 7SK85 (CP200), SIPROTEC 5 7SL86 (CP200), SIPROTEC 5 7SL87 (CP200), SIPROTEC 5 7SS85 (CP200), SIPROTEC 5 7ST85 (CP200), SIPROTEC 5 7UT85 (CP200), SIPROTEC 5 7UT86 (CP200), SIPROTEC 5 7UT87 (CP200), SIPROTEC 5 7VK87 (CP200): Currently no fix is planned
  • SIPROTEC 5 7KE85 (CP300), SIPROTEC 5 7SA82 (CP100), SIPROTEC 5 7SD82 (CP100), SIPROTEC 5 7SJ81 (CP100), SIPROTEC 5 7SJ82 (CP100), SIPROTEC 5 7SK82 (CP100), SIPROTEC 5 7SL82 (CP100), SIPROTEC 5 7ST85 (CP300), SIPROTEC 5 7ST86 (CP300), SIPROTEC 5 7UT82 (CP100): Currently no fix is available
  • SIPROTEC 5 Compact 7SX800 (CP050): Update to V9.90 or later version.
  • SIPROTEC 5 7SA82 (CP150), SIPROTEC 5 7SD82 (CP150), SIPROTEC 5 7SJ81 (CP150), SIPROTEC 5 7SJ82 (CP150), SIPROTEC 5 7SK82 (CP150), SIPROTEC 5 7SL82 (CP150), SIPROTEC 5 7SX82 (CP150), SIPROTEC 5 7SY82 (CP150), SIPROTEC 5 7UT82 (CP150): Update to V9.90 or later version.
  • SIPROTEC 5 6MD84 (CP300), SIPROTEC 5 6MD85 (CP300), SIPROTEC 5 6MD86 (CP300), SIPROTEC 5 6MD89 (CP300), SIPROTEC 5 6MU85 (CP300), SIPROTEC 5 7SA86 (CP300), SIPROTEC 5 7SA87 (CP300), SIPROTEC 5 7SD86 (CP300), SIPROTEC 5 7SD87 (CP300), SIPROTEC 5 7SJ85 (CP300), SIPROTEC 5 7SJ86 (CP300), SIPROTEC 5 7SK85 (CP300), SIPROTEC 5 7SL86 (CP300), SIPROTEC 5 7SL87 (CP300), SIPROTEC 5 7SS85 (CP300), SIPROTEC 5 7SX85 (CP300), SIPROTEC 5 7UM85 (CP300), SIPROTEC 5 7UT85 (CP300), SIPROTEC 5 7UT86 (CP300), SIPROTEC 5 7UT87 (CP300), SIPROTEC 5 7VE85 (CP300), SIPROTEC 5 7VK87 (CP300), SIPROTEC 5 7VU85 (CP300): Update to V9.90 or later version.

Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.

Siemens recommends following grid security guidelines.

For more information see the associated Siemens security advisory SSA-687955 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY
  • February 13, 2025: Initial Publication
CISA

mySCADA myPRO Manager

2 months ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 10.0
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: mySCADA
  • Equipment: myPRO Manager
  • Vulnerabilities: OS Command Injection, Missing Authentication for Critical Function, Cleartext Storage of Sensitive Information, Cross-Site Request Forgery (CSRF)
2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary OS commands, upload files, and obtain sensitive information without providing associated credentials.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

The following mySCADA products are affected:

  • myPRO Manager: Versions prior to 1.4
3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN OS Command ('OS COMMAND INJECTION') CWE-78

The affected product is vulnerable to an OS command injection which could allow a remote attacker to execute arbitrary OS commands.

CVE-2025-25067 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-25067. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.2 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306

The administrative web interface can be accessed without authentication which could allow an unauthorized attacker to retrieve sensitive information and upload files without the associated password.

CVE-2025-24865 has been assigned to this vulnerability. A CVSS v3.1 base score of 10.0 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-24865. A base score of 10.0 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H).

3.2.3 CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312

The affected product stores credentials in cleartext, which could allow an attacker to obtain sensitive information.

CVE-2025-22896 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.6 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2025-22896. A base score of 9.2 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N).

3.2.4 CROSS-SITE REQUEST FORGERY (CSRF) CWE-352

The affected product is vulnerable to cross-site request forgery (CSRF), which could allow an attacker to obtain sensitive information. An attacker would need to trick the victim in to visiting an attacker-controlled website.

CVE-2025-23411 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L).

A CVSS v4 score has also been calculated for CVE-2025-23411. A base score of 5.1 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Czech Republic
3.4 RESEARCHER

Michael Heinzl reported these vulnerabilities to CISA.

4. MITIGATIONS

mySCADA recommends users update to myPRO Manager v1.4

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY
  • February 13, 2025: Initial Publication
CISA

Outback Power Mojave Inverter

2 months ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 8.7
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Outback Power
  • Equipment: Mojave Inverter
  • Vulnerabilities: Use of GET Request Method With Sensitive Query Strings, Exposure of Sensitive Information to an Unauthorized Actor, Command Injection
2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to access sensitive data or inject commands.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

The following versions of Outback Power Mojave Inverter, a system for managing power in a residential grid-connected battery backup system, are affected:

  • Outback Power Mojave Inverter: All versions
3.2 VU;NERABILITY OVERVIEW 3.2.1 Use of GET Request Method With Sensitive Query Strings CWE-598

The Mojave Inverter uses the GET method for sensitive information.

CVE-2025-26473 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated forCVE-2025-26473. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.2.2 Exposure of Sensitive Information to an Unauthorized Actor CWE-200

An attacker may modify the URL to discover sensitive information about the target network.

CVE-2025-25281 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated forCVE-2025-25281. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.2.3 Improper Neutralization of Special Elements used in a Command CWE-77

An attacker may inject commands via specially-crafted post requests.

CVE-2025-24861 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated forCVE-2025-24861. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Energy
  • COUNTRIES/AREAS DEPLOYED: United States
  • COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER

Jon Hurtado of Sandia National Laboratory reported these vulnerabilities to CISA.

4. MITIGATIONS

The Mojave Inverter was a product of Enersys. When Outback Power was split off from Enersys recently, Mojave Inverter was moved to Outback Power, but without the resources to maintain the product. Outback Power may discontinue this product and has not yet addressed these vulnerabilities. CISA recommends disabling the networking features of this product until a replacement product can be acquired.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Disable un-used functions.
  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY
  • February 13, 2025: Initial Publication
CISA

Siemens SIMATIC

2 months ago

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 6.9
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SIMATIC
  • Vulnerability: Observable Discrepancy
2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to identify valid usernames.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

Siemens reports the following SIMATIC products are affected:

  • Siemens SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1513pro-2 PN (6ES7513-2PM03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0): vers:all/<V4.7
  • Siemens SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0): vers:all/<V4.7
  • Siemens SIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CL03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DM03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0): vers:all/<V4.7
  • Siemens SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0): vers:all/<V4.7
  • Siemens SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0): vers:all/<V4.7
  • Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants): vers:all/>=V30.1.0
  • Siemens SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0): vers:all/<V4.7
  • Siemens SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1516pro-2 PN (6ES7516-2PP03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0): vers:all/<V4.7
  • Siemens SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0): vers:all/<V4.7
  • Siemens SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0): vers:all/<V4.7
  • Siemens SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DK03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1513pro F-2 PN (6ES7513-2GM03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0): vers:all/<V4.7
  • Siemens SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP01-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1514SP-2 PN (6ES7514-2DN03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0): vers:all/<V4.7
  • Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-PLCSIM Advanced: vers:all/>=V6.0|<V7.0
  • Siemens SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CM03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0): vers:all/<V4.7
  • Siemens SIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0): vers:all/<V4.7
  • Siemens SIMATIC S7-1500 CPU 1516pro F-2 PN (6ES7516-2GP03-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0): vers:all/>=V3.1.0|<V3.1.2
  • Siemens SIMATIC S7-1500 Software Controller: vers:all/>=V30.1.0
3.2 VULNERABILITY OVERVIEW 3.2.1 OBSERVABLE DISCREPANCY CWE-203

The login functionality of the web server in affected devices does not normalize the response times of login attempts. An unauthenticated remote attacker could exploit this side-channel information to distinguish between valid and invalid usernames.

CVE-2023-37482 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2023-37482. A base score of 6.9 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER

David Henrique Estevam de Andrade reported this vulnerability to Siemens.
Siemens then reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0), SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0), SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DK03-0AB0), SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0), SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CL03-0AB0), SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0), SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0), SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0), SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CM03-0AB0), SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0), SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DM03-0AB0), SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0), SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0), SIMATIC S7-1500 CPU 1513pro F-2 PN (6ES7513-2GM03-0AB0), SIMATIC S7-1500 CPU 1513pro-2 PN (6ES7513-2PM03-0AB0), SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0), SIMATIC S7-1500 CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0), SIMATIC S7-1500 CPU 1514SP-2 PN (6ES7514-2DN03-0AB0), SIMATIC S7-1500 CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0), SIMATIC S7-1500 CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0), SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0), SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0), SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0), SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0), SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0), SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0), SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0), SIMATIC S7-1500 CPU 1516pro F-2 PN (6ES7516-2GP03-0AB0), SIMATIC S7-1500 CPU 1516pro-2 PN (6ES7516-2PP03-0AB0), SIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0), SIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0), SIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0), SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0), SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP01-0AB0), SIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0), SIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0), SIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0), SIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0), SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0), SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0), SIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0), SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0), SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0), SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0), SIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0), SIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0), SIMATIC S7-1500 Software Controller, SIMATIC S7-PLCSIM Advanced, SIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0), SIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0), SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0), SIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0), SIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0): Disable HTTP (Port 80/tcp) and provide web service access through HTTPS (Port 443/tcp) only; the vulnerability is considered as only exploitable via HTTP.
  • SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC S7-1500 Software Controller: Currently no fix is available.
  • SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0), SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DK03-0AB0), SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0), SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CL03-0AB0), SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0), SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0), SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0), SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CM03-0AB0), SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0), SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DM03-0AB0), SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0), SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0), SIMATIC S7-1500 CPU 1513pro F-2 PN (6ES7513-2GM03-0AB0), SIMATIC S7-1500 CPU 1513pro-2 PN (6ES7513-2PM03-0AB0), SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0), SIMATIC S7-1500 CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0), SIMATIC S7-1500 CPU 1514SP-2 PN (6ES7514-2DN03-0AB0), SIMATIC S7-1500 CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0), SIMATIC S7-1500 CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0), SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0), SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0), SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0), SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0), SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0), SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0), SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0), SIMATIC S7-1500 CPU 1516pro F-2 PN (6ES7516-2GP03-0AB0), SIMATIC S7-1500 CPU 1516pro-2 PN (6ES7516-2PP03-0AB0), SIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0), SIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0), SIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0), SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0), SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP01-0AB0), SIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0), SIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0), SIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0), SIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0), SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0), SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0), SIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0), SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0), SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0), SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0), SIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0), SIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0), SIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0), SIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0), SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0), SIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0), SIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0): Update to V3.1.2 or a later version.
  • SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0), SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0): Update to V3.1.2 or later version.
  • SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0): Update to V4.7 or a later version.
  • SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0): Update to V4.7 or a later version.
  • SIMATIC S7-PLCSIM Advanced: Update to V7.0 or a later version.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-195895 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY
  • February 13, 2025: Initial Publication
CISA

Siemens SCALANCE W700

2 months ago

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v3 9.8
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SCALANCE W700
  • Vulnerabilities: Double Free, Improper Restriction of Communication Channel to Intended Endpoints, Improper Resource Shutdown or Release, Inadequate Encryption Strength, Race Condition, Integer Overflow or Wraparound, Out-of-bounds Write, NULL Pointer Dereference, Externally Controlled Reference to a Resource in Another Sphere, Use After Free, Type Confusion, Improper Certificate Validation, Missing Release of Memory after Effective Lifetime, Uncontrolled Resource Consumption, Out-of-bounds Read, Inefficient Regular Expression Complexity, Incorrect Provision of Specified Functionality, Improper Check for Unusual or Exceptional Conditions, Permissive List of Allowed Inputs, Improper Input Validation, Divide By Zero, Forced Browsing, Unchecked Return Value, Truncation of Security-relevant Information, Missing Critical Step in Authentication, OS Command Injection, Excessive Iteration, Exposure of Sensitive Information to an Unauthorized Actor, Observable Discrepancy, Improper Restriction of Operations within the Bounds of a Memory Buffer, Cross-site Scripting, Injection, Improper Access Control
2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to inject code, escalate privileges, execute arbitrary code, compromise system integrity, and cause a denial-of-service condition.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • Siemens SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0): All versions prior to v3.0.0
  • Siemens SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0): All versions prior to v3.0.0
  • Siemens SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0):All versions prior to v3.0.0
  • Siemens SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0): All versions prior to v3.0.0
  • Siemens SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0): All versions prior to v3.0.0
  • Siemens SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0): All versions prior to v3.0.0
  • Siemens SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0):All versions prior to v3.0.0
  • Siemens SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0): All versions prior to v3.0.0
  • Siemens SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0): All versions prior to v3.0.0
  • Siemens SCALANCE WAM763-1 (6GK5763-1AL00-7DA0): All versions prior to v3.0.0
  • Siemens SCALANCE WAM766-1 (6GK5766-1GE00-7DA0): All versions prior to v3.0.0
  • Siemens SCALANCE WUM766-1 (6GK5766-1GE00-3DA0): All versions prior to v3.0.0
  • Siemens SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0): All versions prior to v3.0.0
  • Siemens SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0): All versions prior to v3.0.0
  • Siemens SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0): All versions prior to v3.0.0
  • Siemens SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0): All versions prior to v3.0.0
  • Siemens SCALANCE WUM763-1 (6GK5763-1AL00-3AA0): All versions prior to v3.0.0
  • Siemens SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0): All versions prior to v3.0.0
3.2 VULNERABILITY OVERVIEW 3.2.1 DOUBLE FREE CWE-415

Zhenpeng Lin discovered that the network packet scheduler implementation in the Linux kernel did not properly remove all references to a route filter before freeing it in some situations. A local attacker could use this to cause a denial-of-service (system crash) or execute arbitrary code.

CVE-2022-2588 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.2 IMPROPER RESTRICTION OF COMMUNICATION CHANNEL TO INTENDED ENDPOINTS CWE-923

An issue was found in the Linux kernel in nf_conntrack_irc where the message handling can be confused and incorrectly matches the message. A firewall may be able to be bypassed when users are using unencrypted IRC with nf_conntrack_irc configured.

CVE-2022-2663 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N).

3.2.3 IMPROPER RESOURCE SHUTDOWN OR RELEASE CWE-404

A vulnerability was found in Linux Kernel. It has been declared as problematic. Affected by this vulnerability is the function ipv6_renew_options of the component IPv6 Handler. The manipulation leads to memory leak. The attack can be launched remotely. It is recommended to apply a patch to fix this issue. The identifier VDB-211021 was assigned to this vulnerability.

CVE-2022-3524 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).

3.2.4 INADEQUATE ENCRYPTION STRENGTH CWE-326

A timing based side channel exists in the OpenSSL RSA Decryption implementation which could be sufficient to recover a plaintext across a network in a Bleichenbacher style attack. To achieve a successful decryption an attacker would have to be able to send a very large number of trial messages for decryption. The vulnerability affects all RSA padding modes: PKCS#1 v1.5, RSA-OEAP and RSASVE. For example, in a TLS connection, RSA is commonly used by a client to send an encrypted pre-master secret to the server. An attacker that had observed a genuine connection between a client and a server could use this flaw to send trial messages to the server and record the time taken to process them. After a sufficiently large number of messages the attacker could recover the pre-master secret used for the original connection and thus be able to decrypt the application data sent over that connection.

CVE-2022-4304 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N).

3.2.5 DOUBLE FREE CWE-415

The function PEM_read_bio_ex() reads a PEM file from a BIO and parses and decodes the "name" (e.g. "CERTIFICATE"), any header data and the payload data. If the function succeeds then the "name_out", "header" and "data" arguments are populated with pointers to buffers containing the relevant decoded data. The caller is responsible for freeing those buffers. It is possible to construct a PEM file that results in 0 bytes of payload data. In this case PEM_read_bio_ex() will return a failure code but will populate the header argument with a pointer to a buffer that has already been freed. If the caller also frees this buffer then a double free will occur. This will most likely lead to a crash. This could be exploited by an attacker who has the ability to supply malicious PEM files for parsing to achieve a denial-of-service attack. The functions PEM_read_bio() and PEM_read() are simple wrappers around PEM_read_bio_ex() and therefore these functions are also directly affected. These functions are also called indirectly by a number of other OpenSSL functions including PEM_X509_INFO_read_bio_ex() and SSL_CTX_use_serverinfo_file() which are also vulnerable. Some OpenSSL internal uses of these functions are not vulnerable because the caller does not free the header argument if PEM_read_bio_ex() returns a failure code. These locations include the PEM_read_bio_TYPE() functions as well as the decoders introduced in OpenSSL 3.0. The OpenSSL asn1parse command line application is also impacted by this issue.

CVE-2022-4450 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.6 CONCURRENT EXECUTION USING SHARED RESOURCE WITH IMPROPER SYNCHRONIZATION ('RACE CONDITION') CWE-362

An issue was discovered in include/asm-generic/tlb.h in the Linux kernel before 5.19. Because of a race condition (unmap_mapping_range versus munmap), a device driver can free a page while it still has stale TLB entries. This only occurs in situations with VM_PFNMAP VMAs.

CVE-2022-39188 has been assigned to this vulnerability. A CVSS v3 base score of 4.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.7 INTEGER OVERFLOW OR WRAPAROUND CWE-190

An issue was discovered in the Linux kernel before 5.19. In pxa3xx_gcu_write in drivers/video/fbdev/pxa3xx-gcu.c, the count parameter has a type conflict of size_t versus int, causing an integer overflow and bypassing the size check. After that, because it is used as the third argument to copy_from_user(), a heap overflow may occur. NOTE: the original discoverer disputes that the overflow can actually happen.

CVE-2022-39842 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H).

3.2.8 INTEGER OVERFLOW OR WRAPAROUND CWE-190

An issue was discovered in libxml2 before 2.10.3. When parsing a multi-gigabyte XML document with the XML_PARSE_HUGE parser option enabled, several integer counters can overflow. This results in an attempt to access an array at a negative 2GB offset, typically leading to a segmentation fault.

CVE-2022-40303 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.9 DOUBLE FREE CWE-415

An issue was discovered in libxml2 before 2.10.3. Certain invalid XML entity definitions can corrupt a hash table key, potentially leading to subsequent logic errors. In one case, a double-free can be provoked.

CVE-2022-40304 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.10 OUT-OF-BOUNDS WRITE CWE-787

drivers/usb/mon/mon_bin.c in usbmon in the Linux kernel before 5.19.15 and 6.x before 6.0.1 allows a user-space client to corrupt the monitor's internal memory.

CVE-2022-43750 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).

3.2.11 OUT-OF-BOUNDS WRITE CWE-787

p7zip 16.02 was discovered to contain a heap-buffer-overflow vulnerability via the function NArchive::NZip::CInArchive::FindCd(bool) at CPP/7zip/Archive/Zip/ZipIn.cpp.

CVE-2022-47069 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.12 NULL POINTER DEREFERENCE CWE-476

In the Linux kernel before 6.1.6, a NULL pointer dereference bug in the traffic control subsystem allows an unprivileged user to trigger a denial-of-service (system crash) via a crafted traffic control configuration that is set up with "tc qdisc" and "tc class" commands. This affects qdisc_graft in net/sched/sch_api.c.

CVE-2022-47929 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.13 EXTERNALLY CONTROLLED REFERENCE TO A RESOURCE IN ANOTHER SPHERE CWE-610

The current implementation of the prctl syscall does not issue an IBPB immediately during the syscall. The ib_prctl_set  function updates the Thread Information Flags (TIFs) for the task and updates the SPEC_CTRL MSR on the function __speculation_ctrl_update, but the IBPB is only issued on the next schedule, when the TIF bits are checked. This leaves the victim vulnerable to values already injected on the BTB, prior to the prctl syscall.  The patch that added the support for the conditional mitigation via prctl (ib_prctl_set) dates back to the kernel 4.9.176. We recommend upgrading past commit a664ec9158eeddd75121d39c9a0758016097fa96.

CVE-2023-0045 has been assigned to this vulnerability. A CVSS v3 base score of 4.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N).

3.2.14 USE AFTER FREE CWE-416

The public API function BIO_new_NDEF is a helper function used for streaming ASN.1 data via a BIO. It is primarily used internally to OpenSSL to support the SMIME, CMS and PKCS7 streaming capabilities, but may also be called directly by end user applications. The function receives a BIO from the caller, prepends a new BIO_f_asn1 filter BIO onto the front of it to form a BIO chain, and then returns the new head of the BIO chain to the caller. Under certain conditions, for example if a CMS recipient public key is invalid, the new filter BIO is freed and the function returns a NULL result indicating a failure. However, in this case, the BIO chain is not properly cleaned up and the BIO passed by the caller still retains internal pointers to the previously freed filter BIO. If the caller then goes on to call BIO_pop() on the BIO then a use-after-free will occur. This will most likely result in a crash. This scenario occurs directly in the internal function B64_write_ASN1() which may cause BIO_new_NDEF() to be called and will subsequently call BIO_pop() on the BIO. This internal function is in turn called by the public API functions PEM_write_bio_ASN1_stream, PEM_write_bio_CMS_stream, PEM_write_bio_PKCS7_stream, SMIME_write_ASN1, SMIME_write_CMS and SMIME_write_PKCS7. Other public API functions that may be impacted by this include i2d_ASN1_bio_stream, BIO_new_CMS, BIO_new_PKCS7, i2d_CMS_bio_stream and i2d_PKCS7_bio_stream. The OpenSSL cms and smime command line applications are similarly affected.

CVE-2023-0215 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.15 ACCESS OF RESOURCE USING INCOMPATIBLE TYPE ('TYPE CONFUSION') CWE-843

There is a type confusion vulnerability relating to X.400 address processing inside an X.509 GeneralName. X.400 addresses were parsed as an ASN1_STRING but the public structure definition for GENERAL_NAME incorrectly specified the type of the x400Address field as ASN1_TYPE. This field is subsequently interpreted by the OpenSSL function GENERAL_NAME_cmp as an ASN1_TYPE rather than an ASN1_STRING. When CRL checking is enabled (i.e. the application sets the X509_V_FLAG_CRL_CHECK flag), this vulnerability may allow an attacker to pass arbitrary pointers to a memcmp call, enabling them to read memory contents or enact a denial-of-service. In most cases, the attack requires the attacker to provide both the certificate chain and CRL, neither of which need to have a valid signature. If the attacker only controls one of these inputs, the other input must already contain an X.400 address as a CRL distribution point, which is uncommon. As such, this vulnerability is most likely to only affect applications which have implemented their own functionality for retrieving CRLs over a network.

CVE-2023-0286 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H).

3.2.16 IMPROPER CERTIFICATE VALIDATION CWE-295

A security vulnerability has been identified in all supported versions of OpenSSL related to the verification of X.509 certificate chains that include policy constraints. Attackers may be able to exploit this vulnerability by creating a malicious certificate chain that triggers exponential use of computational resources, leading to a denial-of-service (DoS) attack on affected systems. Policy processing is disabled by default but can be enabled by passing the -policy argument to the command line utilities or by calling the X509_VERIFY_PARAM_set1_policies() function.

CVE-2023-0464 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.17 IMPROPER CERTIFICATE VALIDATION CWE-295

Applications that use a non-default option when verifying certificates may be vulnerable to an attack from a malicious CA to circumvent certain checks. Invalid certificate policies in leaf certificates are silently ignored by OpenSSL and other certificate policy checks are skipped for that certificate. A malicious CA could use this to deliberately assert invalid certificate policies in order to circumvent policy checking on the certificate altogether. Policy processing is disabled by default but can be enabled by passing the -policy argument to the command line utilities or by calling the X509_VERIFY_PARAM_set1_policies()  function.

CVE-2023-0465 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N).

3.2.18 IMPROPER CERTIFICATE VALIDATION CWE-295

The function X509_VERIFY_PARAM_add0_policy() is documented to implicitly enable the certificate policy check when doing certificate verification. However the implementation of the function does not enable the check which allows certificates with invalid or incorrect policies to pass the certificate verification. As suddenly enabling the policy check could break existing deployments it was decided to keep the existing behavior of the X509_VERIFY_PARAM_add0_policy() function. Instead the applications that require OpenSSL to perform certificate policy check need to use X509_VERIFY_PARAM_set1_policies() or explicitly enable the policy check by calling X509_VERIFY_PARAM_set_flags() with the X509_V_FLAG_POLICY_CHECK flag argument. Certificate policy checks are disabled by default in OpenSSL and are not commonly used by applications.

CVE-2023-0466 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N).

3.2.19 USE AFTER FREE CWE-416

A use-after-free flaw was found in qdisc_graft in net/sched/sch_api.c in the Linux Kernel due to a race problem. This flaw leads to a denial-of-service issue. If patch ebda44da44f6 ("net: sched: fix race condition in qdisc_graft()") not applied yet, then kernel could be affected.

CVE-2023-0590 has been assigned to this vulnerability. A CVSS v3 base score of 4.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.20 OUT-OF-BOUNDS WRITE CWE-787

A memory corruption flaw was found in the Linux kernel's human interface device (HID) subsystem in how a user inserts a malicious USB device. This flaw allows a local user to crash or potentially escalate their privileges on the system.

CVE-2023-1073 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the CVSS vector string is (CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.21 MISSING RELEASE OF MEMORY AFTER EFFECTIVE LIFETIME CWE-401

A memory leak flaw was found in the Linux kernel's Stream Control Transmission Protocol. This issue may occur when a user starts a malicious networking service and someone connects to this service. This could allow a local user to starve resources, causing a denial-of-service.

CVE-2023-1074 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.22 USE AFTER FREE CWE-416

A flaw use after free in the Linux kernel integrated infrared receiver/transceiver driver was found in the way user detaching rc device. A local user could use this flaw to crash the system or potentially escalate their privileges on the system.

CVE-2023-1118 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.23 UNCONTROLLED RESOURCE CONSUMPTION CWE-400

A hash collision flaw was found in the IPv6 connection lookup table in the Linux kernel's IPv6 functionality when a user makes a new kind of SYN flood attack. A user located in the local network or with a high bandwidth connection can increase the CPU usage of the server that accepts IPV6 connections up to 95%.

CVE-2023-1206 has been assigned to this vulnerability. A CVSS v3 base score of 5.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.24 OUT-OF-BOUNDS READ CWE-125

A slab-out-of-bound read problem was found in brcmf_get_assoc_ies in drivers/net/wireless/broadcom/brcm80211/brcmfmac/cfg80211.c in the Linux Kernel. This issue could occur when assoc_info->req_len data is bigger than the size of the buffer, defined as WL_EXTRA_BUF_MAX, leading to a denial-of-service.

CVE-2023-1380 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H).

3.2.25 USE AFTER FREE CWE-416

A flaw use after free in the Linux kernel Xircom 16-bit PCMCIA (PC-card) Ethernet driver was found.A local user could use this flaw to crash the system or potentially escalate their privileges on the system.

CVE-2023-1670 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.26 OUT-OF-BOUNDS WRITE CWE-787

An out-of-bounds write vulnerability was found in the Linux kernel's SLIMpro I2C device driver. The user space "data->block[0]" variable was not capped to a number between 0-255 and was used as the size of a memcpy, possibly writing beyond the end of dma_buffer. This flaw could allow a local privileged user to crash the system or potentially achieve code execution.

CVE-2023-2194 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).

3.2.27 INEFFICIENT REGULAR EXPRESSION COMPLEXITY CWE-1333

Checking excessively long DH keys or parameters may be very slow. Applications that use the functions DH_check(), DH_check_ex() or EVP_PKEY_param_check() to check a DH key or DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a denial-of-service. The function DH_check() performs various checks on DH parameters. One of those checks confirms that the modulus ('p' parameter) is not too large. Trying to use a very large modulus is slow and OpenSSL will not normally use a modulus which is over 10,000 bits in length. However the DH_check() function checks numerous aspects of the key or parameters that have been supplied. Some of those checks use the supplied modulus value even if it has already been found to be too large. An application that calls DH_check() and supplies a key or parameters obtained from an untrusted source could be vulnerable to a denial-of-service attack. The function DH_check() is itself called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_ex() and EVP_PKEY_param_check(). Also vulnerable are the OpenSSL dhparam and pkeyparam command line applications when using the '-check' option. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.

CVE-2023-3446 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.2.28 OUT-OF-BOUNDS WRITE CWE-787

An out-of-bounds write vulnerability in the Linux kernel's net/sched: sch_qfq component can be exploited to achieve local privilege escalation. The qfq_change_agg() function in net/sched/sch_qfq.c allows an out-of-bounds write because lmax is updated according to packet sizes without bounds checks.

CVE-2023-3611 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.29 USE AFTER FREE CWE-416

A use-after-free vulnerability in the Linux kernel's net/sched: sch_hfsc (HFSC qdisc traffic control) component can be exploited to achieve local privilege escalation. If a class with a link-sharing curve (i.e. with the HFSC_FSC flag set) has a parent without a link-sharing curve, then init_vf() will call vttree_insert() on the parent, but vttree_remove() will be skipped in update_vf(). This leaves a dangling pointer that can cause a use-after-free. We recommend upgrading past commit b3d26c5702c7d6c45456326e56d2ccf3f103e60f.

CVE-2023-4623 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.30 USE AFTER FREE CWE-416

A use-after-free vulnerability in the Linux kernel's net/sched: sch_qfq component can be exploited to achieve local privilege escalation. When the plug qdisc is used as a class of the qfq qdisc, sending network packets triggers use-after-free in qfq_dequeue() due to the incorrect .peek handler of sch_plug and lack of error checking in agg_dequeue(). We recommend upgrading past commit 8fc134fee27f2263988ae38920bc03da416b03d8.

CVE-2023-4921 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.31 INCORRECT PROVISION OF SPECIFIED FUNCTIONALITY CWE-684

A bug has been identified in the processing of key and initialization vector (IV) lengths. This can lead to potential truncation or overruns during the initialisation of some symmetric ciphers. A truncation in the IV can result in non-uniqueness, which could result in loss of confidentiality for some cipher modes. When calling EVP_EncryptInit_ex2(), EVP_DecryptInit_ex2() or EVP_CipherInit_ex2() the provided OSSL_PARAM array is processed after the key and IV have been established. Any alterations to the key length, via the "keylen" parameter or the IV length, via the "ivlen" parameter, within the OSSL_PARAM array will not take effect as intended, potentially causing truncation or overr-eading of these values. The following ciphers and cipher modes are impacted: RC2, RC4, RC5, CCM, GCM and OCB. For the CCM, GCM and OCB cipher modes, truncation of the IV can result in loss of confidentiality. For example, when following NIST's SP 800-38D section 8.2.1 guidance for constructing a deterministic IV for AES in GCM mode, truncation of the counter portion could lead to IV reuse. Both truncations and overruns of the key and overruns of the IV will produce incorrect results and could, in some cases, trigger a memory exception. However, these issues are not currently assessed as security critical. Changing the key and/or IV lengths is not considered to be a common operation and the vulnerable API was recently introduced. Furthermore it is likely that application developers will have spotted this problem during testing since decryption would fail unless both peers in the communication were similarly vulnerable. For these reasons we expect the probability of an application being vulnerable to this to be quite low. However if an application is vulnerable then this issue is considered very serious. For these reasons we have assessed this issue as Moderate severity overall. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this because the issue lies outside of the FIPS provider boundary. OpenSSL 3.1 and 3.0 are vulnerable to this issue.

CVE-2023-5363 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

3.2.32 IMPROPER CHECK FOR UNUSUAL OR EXCEPTIONAL CONDITIONS CWE-754

Generating excessively long X9.42 DH keys or checking excessively long X9.42 DH keys or parameters may be very slow. Applications that use the functions DH_generate_key() to generate an X9.42 DH key may experience long delays. Likewise, applications that use DH_check_pub_key(), DH_check_pub_key_ex() or EVP_PKEY_public_check() to check an X9.42 DH key or X9.42 DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a denial-of-service. While DH_check() performs all the necessary checks (as of CVE-2023-3817), DH_check_pub_key() doesn't make any of these checks, and is therefore vulnerable for excessively large P and Q parameters. Likewise, while DH_generate_key() performs a check for an excessively large P, it doesn't check for an excessively large Q. An application that calls DH_generate_key() or DH_check_pub_key() and supplies a key or parameters obtained from an untrusted source could be vulnerable to a denial-of-service attack. DH_generate_key() and DH_check_pub_key() are also called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_pub_key_ex(), EVP_PKEY_public_check(), and EVP_PKEY_generate(). Also vulnerable are the OpenSSL pkey command line application when using the "-pubcheck" option, as well as the OpenSSL genpkey command line application. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.

CVE-2023-5678 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.2.33 OUT-OF-BOUNDS WRITE CWE-787

A heap out-of-bounds write vulnerability in the Linux kernel's Linux Kernel Performance Events (perf) component can be exploited to achieve local privilege escalation. If perf_read_group() is called while an event's sibling_list is smaller than its child's sibling_list, it can increment or write to memory locations outside of the allocated buffer. We recommend upgrading past commit 32671e3799ca2e4590773fd0e63aaa4229e50c06.

CVE-2023-5717 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.34 OUT-OF-BOUNDS WRITE CWE-787

The POLY1305 MAC (message authentication code) implementation contains a bug that might corrupt the internal state of applications running on PowerPC CPU based platforms if the CPU provides vector instructions. If an attacker can influence whether the POLY1305 MAC algorithm is used, the application state might be corrupted with various application dependent consequences. The POLY1305 MAC (message authentication code) implementation in OpenSSL for PowerPC CPUs restores the contents of vector registers in a different order than they are saved. Thus the contents of some of these vector registers are corrupted when returning to the caller. The vulnerable code is used only on newer PowerPC processors supporting the PowerISA 2.07 instructions. The consequences of this kind of internal application state corruption can be various - from no consequences, if the calling application does not depend on the contents of non-volatile XMM registers at all, to the worst consequences, where the attacker could get complete control of the application process. However unless the compiler uses the vector registers for storing pointers, the most likely consequence, if any, would be an incorrect result of some application dependent calculations or a crash leading to a denial-of-service. The POLY1305 MAC algorithm is most frequently used as part of the CHACHA20-POLY1305 AEAD (authenticated encryption with associated data) algorithm. The most common usage of this AEAD cipher is with TLS protocol versions 1.2 and 1.3. If this cipher is enabled on the server a malicious client can influence whether this AEAD cipher is used. This implies that TLS server applications using OpenSSL can be potentially impacted. However we are currently not aware of any concrete application that would be affected by this issue therefore we consider this a Low severity security issue.

CVE-2023-6129 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:H).

3.2.35 UNCONTROLLED RESOURCE CONSUMPTION CWE-400

Checking excessively long invalid RSA public keys may take a long time. Applications that use the function EVP_PKEY_public_check() to check RSA public keys may experience long delays. Where the key that is being checked has been obtained from an untrusted source this may lead to a denial-of-service. When function EVP_PKEY_public_check() is called on RSA public keys, a computation is done to confirm that the RSA modulus, n, is composite. For valid RSA keys, n is a product of two or more large primes and this computation completes quickly. However, if n is an overly large prime, then this computation would take a long time. An application that calls EVP_PKEY_public_check() and supplies an RSA key obtained from an untrusted source could be vulnerable to a denial-of-service attack. The function EVP_PKEY_public_check() is not called from other OpenSSL functions however it is called from the OpenSSL pkey command line application. For that reason that application is also vulnerable if used with the '-pubin' and '-check' options on untrusted data. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are affected by this issue.

CVE-2023-6237 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.36 PERMISSIVE LIST OF ALLOWED INPUTS CWE-183

A flaw was found in iperf, a utility for testing network performance using TCP, UDP, and SCTP. A malicious or malfunctioning client can send less than the expected amount of data to the iperf server, which can cause the server to hang indefinitely waiting for the remainder or until the connection gets closed. This will prevent other connections to the server, leading to a denial-of-service.

CVE-2023-7250 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.2.37 ACCESS OF RESOURCE USING INCOMPATIBLE TYPE ('TYPE CONFUSION') CWE-843

cbq_classify in net/sched/sch_cbq.c in the Linux kernel through 6.1.4 allows attackers to cause a denial-of-service (slab-out-of-bounds read) because of type confusion (non-negative numbers can sometimes indicate a TC_ACT_SHOT condition rather than valid classification results).

CVE-2023-23454 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.38 ACCESS OF RESOURCE USING INCOMPATIBLE TYPE ('TYPE CONFUSION') CWE-843

atm_tc_enqueue in net/sched/sch_atm.c in the Linux kernel through 6.1.4 allows attackers to cause a denial-of-service because of type confusion (non-negative numbers can sometimes indicate a TC_ACT_SHOT condition rather than valid classification results).

CVE-2023-23455 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.39 INTEGER OVERFLOW OR WRAPAROUND CWE-190

In rndis_query_oid in drivers/net/wireless/rndis_wlan.c in the Linux kernel through 6.1.5, there is an integer overflow in an addition.

CVE-2023-23559 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.40 DOUBLE FREE CWE-415

In the Linux kernel before 6.1.13, there is a double free in net/mpls/af_mpls.c upon an allocation failure (for registering the sysctl table under a new location) during the renaming of a device.

CVE-2023-26545 has been assigned to this vulnerability. A CVSS v3 base score of 4.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.41 NULL POINTER DEREFERENCE CWE-476

In libxml2 before 2.10.4, parsing of certain invalid XSD schemas can lead to a NULL pointer dereference and subsequently a segfault. This occurs in xmlSchemaFixupComplexType in xmlschemas.c.

CVE-2023-28484 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).

3.2.42 IMPROPER INPUT VALIDATION CWE-20

Memory corruption in Core Services while executing the command for removing a single event listener.

CVE-2023-28578 has been assigned to this vulnerability. A CVSS v3 base score of 9.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).

3.2.43 DOUBLE FREE CWE-415

An issue was discovered in libxml2 before 2.10.4. When hashing empty dict strings in a crafted XML document, xmlDictComputeFastKey in dict.c can produce non-deterministic values, leading to various logic and memory errors, such as a double free. This behavior occurs because there is an attempt to use the first byte of an empty string, and any value is possible (not solely the '\0' value).

CVE-2023-29469 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).

3.2.44 DIVIDE BY ZERO CWE-369

An issue was discovered in drivers/mtd/ubi/cdev.c in the Linux kernel 6.2. There is a divide-by-zero error in do_div(sz,mtd->erasesize), used indirectly by ctrl_cdev_ioctl, when mtd->erasesize is 0.

CVE-2023-31085 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.45 IMPROPER INPUT VALIDATION CWE-20

Improper validation in a model specific register (MSR) could allow a malicious program with ring0 access to modify SMM configuration while SMI lock is enabled, potentially leading to arbitrary code execution.

CVE-2023-31315 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H).

3.2.46 OUT-OF-BOUNDS WRITE CWE-787

Linux Kernel nftables Out-Of-Bounds Read/Write Vulnerability; nft_byteorder poorly handled vm register contents when CAP_NET_ADMIN is in any user or network namespace

CVE-2023-35001 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.47 OUT-OF-BOUNDS READ CWE-125

A flaw was found in the Netfilter subsystem in the Linux kernel. The xt_u32 module did not validate the fields in the xt_u32 structure. This flaw allows a local privileged attacker to trigger an out-of-bounds read by setting the size fields with a value beyond the array boundaries, leading to a crash or information disclosure.

CVE-2023-39192 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:L).

3.2.48 OUT-OF-BOUNDS READ CWE-125

A flaw was found in the Netfilter subsystem in the Linux kernel. The sctp_mt_check did not validate the flag_count field. This flaw allows a local privileged (CAP_NET_ADMIN) attacker to trigger an out-of-bounds read, leading to a crash or information disclosure.

CVE-2023-39193 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L).

3.2.49 NULL POINTER DEREFERENCE CWE-476

A NULL pointer dereference flaw was found in the Linux kernel ipv4 stack. The socket buffer (skb) was assumed to be associated with a device before calling __ip_options_compile, which is not always the case if the skb is re-routed by ipvs. This issue may allow a local user with CAP_NET_ADMIN privileges to crash the system.

CVE-2023-42754 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.50 NULL POINTER DEREFERENCE CWE-476

Transient DOS while key unwrapping process, when the given encrypted key is empty or NULL.

CVE-2023-43522 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.51 DIRECT REQUEST ('FORCED BROWSING') CWE-425

Affected devices do not properly validate the authentication when performing certain modifications in the web interface allowing an authenticated attacker to influence the user interface configured by an administrator.

CVE-2023-44320 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N).

3.2.52 UNCHECKED RETURN VALUE CWE-252

Affected devices can be configured to send emails when certain events occur on the device. When presented with an invalid response from the SMTP server, the device triggers an error that disrupts email sending. An attacker with access to the network can use this to do disable notification of users when certain events occur.

CVE-2023-44322 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.2.53 INTEGER OVERFLOW OR WRAPAROUND CWE-190

MiniZip in zlib through 1.3 has an integer overflow and resultant heap-based buffer overflow in zipOpenNewFileInZip4_64 via a long filename, comment, or extra field. NOTE: MiniZip is not a supported part of the zlib product.

CVE-2023-45853 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.54 OUT-OF-BOUNDS WRITE CWE-787

An issue was discovered in lib/kobject.c in the Linux kernel before 6.2.3. With root access, an attacker can trigger a race condition that results in a fill_kobj_path out-of-bounds write.

CVE-2023-45863 has been assigned to this vulnerability. A CVSS v3 base score of 6.4 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H).

3.2.55 TRUNCATION OF SECURITY-RELEVANT INFORMATION CWE-222

The SSH transport protocol with certain OpenSSH extensions, found in OpenSSH before 9.6 and other products, allows remote attackers to bypass integrity checks such that some packets are omitted (from the extension negotiation message), and a client and server may consequently end up with a connection for which some security features have been downgraded or disabled, aka a Terrapin attack. This occurs because the SSH Binary Packet Protocol (BPP), implemented by these extensions, mishandles the handshake phase and mishandles use of sequence numbers. For example, there is an effective attack against SSH's use of ChaCha20-Poly1305 (and CBC with Encrypt-then-MAC). The bypass occurs in chacha20-poly1305@openssh.com and (if CBC is used) the -etm@openssh.com MAC algorithms. This also affects Maverick Synergy Java SSH API before 3.1.0-SNAPSHOT, Dropbear through 2022.83, Ssh before 5.1.1 in Erlang/OTP, PuTTY before 0.80, AsyncSSH before 2.14.2, golang.org/x/crypto before 0.17.0, libssh before 0.10.6, libssh2 through 1.11.0, Thorn Tech SFTP Gateway before 3.4.6, Tera Term before 5.1, Paramiko before 3.4.0, jsch before 0.2.15, SFTPGo before 2.5.6, Netgate pfSense Plus through 23.09.1, Netgate pfSense CE through 2.7.2, HPN-SSH through 18.2.0, ProFTPD before 1.3.8b (and before1.3.9rc2), ORYX CycloneSSH before 2.3.4, NetSarang XShell 7 before Build 0144, CrushFTP before 10.6.0, ConnectBot SSH library before 2.2.22, Apache MINA sshd through 2.11.0, sshj through 0.37.0, TinySSH through 20230101, trilead-ssh2 6401, the net-ssh gem 7.2.0 for Ruby, the mscdex ssh2 module before 1.15.0 for Node.js, the thrussh library before 0.35.1 for Rust, and the Russh crate before 0.40.2 for Rust; and there could be effects on Bitvise SSH through 9.31.

CVE-2023-48795 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N).

3.2.56 MISSING CRITICAL STEP IN AUTHENTICATION CWE-304

In ssh-agent in OpenSSH before 9.6, certain destination constraints can be incompletely applied. When destination constraints are specified during addition of PKCS#11-hosted private keys, these constraints are only applied to the first key, even if a PKCS#11 token returns multiple keys.

CVE-2023-51384 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).

3.2.57 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN OS COMMAND ('OS COMMAND INJECTION') CWE-78

In ssh in OpenSSH before 9.6, OS command injection might occur if a user name or host name has shell meta characters, and this name is referenced by an expansion token in certain situations. For example, an untrusted Git repository can have a submodule with shell meta characters in a user name or host name.

CVE-2023-51385 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N).

3.2.58 NULL POINTER DEREFERENCE CWE-476

Processing a maliciously formatted PKCS12 file may lead OpenSSL to crash leading to a potential denial-of-service attack

CVE-2024-0727 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).

3.2.59 UNCONTROLLED RESOURCE CONSUMPTION CWE-400

Some non-default TLS server configurations can cause unbounded memory growth when processing TLSv1.3 sessions. An attacker may exploit certain server configurations to trigger unbounded memory growth that would lead to a denial-of-service This problem can occur in TLSv1.3 if the non-default SSL_OP_NO_TICKET option is being used (but not if early_data support is also configured and the default anti-replay protection is in use). In this case, under certain conditions, the session cache can get into an incorrect state and it will fail to flush properly as it fills. The session cache will continue to grow in an unbounded manner. A malicious client could deliberately create the scenario for this failure to force a denial-of-service. It may also happen by accident in normal operation. This issue only affects TLS servers supporting TLSv1.3. It does not affect TLS clients. The FIPS modules in 3.2, 3.1 and 3.0 are not affected by this issue. OpenSSL 1.0.2 is also not affected by this issue.

CVE-2024-2511 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.2.60 EXCESSIVE ITERATION CWE-834

Checking excessively long DSA keys or parameters may be very slow. Applications that use the functions EVP_PKEY_param_check() or EVP_PKEY_public_check() to check a DSA public key or DSA parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a denial-of-service. The functions EVP_PKEY_param_check() or EVP_PKEY_public_check() perform various checks on DSA parameters. Some of those computations take a long time if the modulus (p parameter) is too large. Trying to use a very large modulus is slow and OpenSSL will not allow using public keys with a modulus which is over 10,000 bits in length for signature verification. However the key and parameter check functions do not limit the modulus size when performing the checks. An application that calls EVP_PKEY_param_check() or EVP_PKEY_public_check() and supplies a key or parameters obtained from an untrusted source could be vulnerable to a denial-of-ervice attack. These functions are not called by OpenSSL itself on untrusted DSA keys so only applications that directly call these functions may be vulnerable. Also vulnerable are the OpenSSL pkey and pkeyparam command line applications when using the -check option. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are affected by this issue.

CVE-2024-4603 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.2.61 USE AFTER FREE CWE-416

Calling the OpenSSL API function SSL_free_buffers may cause memory to be accessed that was previously freed in some situations

CVE-2024-4741 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.62 EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200

Calling the OpenSSL API function SSL_select_next_proto with an empty supported client protocols buffer may cause a crash or memory contents to be sent to the peer. A buffer over-read can have a range of potential consequences such as unexpected application behavior or a crash. In particular this issue could result in up to 255 bytes of arbitrary private data from memory being sent to the peer leading to a loss of confidentiality. However, only applications that directly call the SSL_select_next_proto function with a 0 length list of supported client protocols are affected by this issue. This would normally never be a valid scenario and is typically not under attacker control but may occur by accident in the case of a configuration or programming error in the calling application. The OpenSSL API function SSL_select_next_proto is typically used by TLS applications that support ALPN (Application Layer Protocol Negotiation) or NPN (Next Protocol Negotiation). NPN is older, was never standardized and is deprecated in favour of ALPN. We believe that ALPN is significantly more widely deployed than NPN. The SSL_select_next_proto function accepts a list of protocols from the server and a list of protocols from the client and returns the first protocol that appears in the server list that also appears in the client list. In the case of no overlap between the two lists it returns the first item in the client list. In either case it will signal whether an overlap between the two lists was found. In the case where SSL_select_next_proto is called with a zero length client list it fails to notice this condition and returns the memory immediately following the client list pointer (and reports that there was no overlap in the lists). This function is typically called from a server side application callback for ALPN or a client side application callback for NPN. In the case of ALPN the list of protocols supplied by the client is guaranteed by libssl to never be zero in length. The list of server protocols comes from the application and should never normally be expected to be of zero length. In this case if the SSL_select_next_proto function has been called as expected (with the list supplied by the client passed in the client/client_len parameters), then the application will not be vulnerable to this issue. If the application has accidentally been configured with a zero length server list, and has accidentally passed that zero length server list in the client/client_len parameters, and has additionally failed to correctly handle a "no overlap" response (which would normally result in a handshake failure in ALPN) then it will be vulnerable to this problem. In the case of NPN, the protocol permits the client to opportunistically select a protocol when there is no overlap. OpenSSL returns the first client protocol in the no overlap case in support of this. The list of client protocols comes from the application and should never normally be expected to be of zero length. However if the SSL_select_next_proto function is accidentally called with a client_len of 0 then an invalid memory pointer will be returned instead. If the application uses this output as the opportunistic protocol then the loss of confidentiality will occur. This issue has been assessed as Low severity because applications are most likely to be vulnerable if they are using NPN instead of ALPN - but NPN is not widely used. It also requires an application configuration or programming error. Finally, this issue would not typically be under attacker control making active exploitation unlikely. The FIPS modules in 3.3, 3.2, 3.1 and 3.0 are not affected by this issue. Due to the low severity of this issue we are not issuing new releases of OpenSSL at this time. The fix will be included in the next releases when they become available.

CVE-2024-5535 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N).

3.2.63 ACCESS OF RESOURCE USING INCOMPATIBLE TYPE ('TYPE CONFUSION') CWE-843

Applications performing certificate name checks (e.g., TLS clients checking server certificates) may attempt to read an invalid memory address resulting in abnormal termination of the application process. Impact summary: Abnormal termination of an application can a cause a denial-of-service. Applications performing certificate name checks (e.g., TLS clients checking server certificates) may attempt to read an invalid memory address when comparing the expected name with an otherName subject alternative name of an X.509 certificate. This may result in an exception that terminates the application program. Note that basic certificate chain validation (signatures, dates, ...) is not affected, the denial-of-service can occur only when the application also specifies an expected DNS name, Email address or IP address. TLS servers rarely solicit client certificates, and even when they do, they generally don't perform a name check against a reference identifier (expected identity), but rather extract the presented identity after checking the certificate chain. So TLS servers are generally not affected and the severity of the issue is Moderate. The FIPS modules in 3.3, 3.2, 3.1 and 3.0 are not affected by this issue.

CVE-2024-6119 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

3.2.64 OUT-OF-BOUNDS WRITE CWE-787

Use of the low-level GF(2m) elliptic curve APIs with untrusted explicit values for the field polynomial can lead to out-of-bounds memory reads or writes. Impact summary: Out of bound memory writes can lead to an application crash or even a possibility of a remote code execution, however, in all the protocols involving Elliptic Curve Cryptography that we're aware of, either only "named curves" are supported, or, if explicit curve parameters are supported, they specify an X9.62 encoding of binary (GF(2m)) curves that can't represent problematic input values. Thus the likelihood of existence of a vulnerable application is low. In particular, the X9.62 encoding is used for ECC keys in X.509 certificates, so problematic inputs cannot occur in the context of processing X.509 certificates. Any problematic use-cases would have to be using an "exotic" curve encoding. The affected APIs include: EC_GROUP_new_curve_GF2m(), EC_GROUP_new_from_params(), and various supporting BN_GF2m_*() functions. Applications working with "exotic" explicit binary (GF(2m)) curve parameters, that make it possible to represent invalid field polynomials with a zero constant term, via the above or similar APIs, may terminate abruptly as a result of reading or writing outside of array bounds. Remote code execution cannot easily be ruled out. The FIPS modules in 3.3, 3.2, 3.1 and 3.0 are not affected by this issue.

CVE-2024-9143 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N).

3.2.65 UNCONTROLLED RESOURCE CONSUMPTION CWE-400

The integrated ICMP service of the network stack of affected devices can be forced to exhaust its available memory resources when receiving specially crafted messages targeting IP fragment re-assembly. This could allow an unauthenticated remote attacker to cause a temporary denial-of-service condition of the ICMP service, other communication services are not affected. Affected devices will resume normal operation after the attack terminates.

CVE-2024-23814 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.2.66 OBSERVABLE DISCREPANCY CWE-203

iPerf3 before 3.17, when used with OpenSSL before 3.2.0 as a server with RSA authentication, allows a timing side channel in RSA decryption operations. This side channel could be sufficient for an attacker to recover credential plaintext. It requires the attacker to send a large number of messages for decryption, as described in "Everlasting ROBOT: the Marvin Attack" by Hubert Kario.

CVE-2024-26306 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N).

3.2.67 IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119

memory corruption when an invalid firehose patch command is invoked.

CVE-2024-33016 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.68 IMPROPER INPUT VALIDATION CWE-20

Affected devices truncates usernames longer than 15 characters when accessed via SSH or Telnet. This could allow an attacker to compromise system integrity.

CVE-2024-50560 has been assigned to this vulnerability. A CVSS v3 base score of 3.1 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:N).

3.2.69 IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION ('CROSS-SITE SCRIPTING') CWE-79

Affected devices do not properly sanitize the filenames before uploading. This could allow an authenticated remote attacker to compromise of integrity of the system.

CVE-2024-50561 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N).

3.2.70 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS IN OUTPUT USED BY A DOWNSTREAM COMPONENT ('INJECTION') CWE-74

Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.

CVE-2024-50572 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).

3.2.71 IMPROPER INPUT VALIDATION CWE-20

Affected devices do not properly validate input while loading the configuration files. This could allow an authenticated remote attacker to execute arbitrary shell commands on the device.

CVE-2025-24499 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).

3.2.72 IMPROPER ACCESS CONTROL CWE-284

Affected devices with role user is affected by incorrect authorization in SNMPv3 View configuration. This could allow an attacker to change the View Type of SNMPv3 Views.

CVE-2025-24532 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-769027 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY
  • February 13, 2025: Initial Publication
CISA

ORing IAP-420

2 months ago

View CSAF

1. EXECUTIVE SUMMARY
  • CVSS v4 8.6
  • ATTENTION: Exploitable remotely/low attack complexity/public exploits are available
  • Vendor: ORing
  • Equipment: IAP-20
  • Vulnerabilities: Cross-site Scripting, Command Injection
2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to invoke commands to compromise the device via the management interface.

3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS

The following ORing products are affected:

  • IAP-420: Versions 2.01e and prior
3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION ('CROSS-SITE SCRIPTING') CWE-79

A stored cross-site scripting can be triggered by placing JavaScript code into the SSID input field of the web interface. An attacker could exploit this vulnerability by luring an authenticated user to visit a malicious website.

CVE-2024-5410 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2024-5410. A base score of 8.2 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:H/VI:N/VA:H/SC:N/SI:N/SA:H).

3.2.2 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77

The filename parameter of a configuration file upload is prone to a command injection vulnerability. This vulnerability can only be exploited if a user is authenticated to the web interface. An attacker could invoke commands and gain full control over the device.

CVE-2024-5411 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.6 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-5411. A base score of 8.6 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:H).

3.3 BACKGROUND
  • CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Critical Manufacturing, Energy, Transportation Systems
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Taiwan
3.4 RESEARCHER

CISA discovered public proof of concept (PoC) as authored by Thomas Weber of CyberDanube and reported it to ORing.

4. MITIGATIONS

ORing is aware of the vulnerabilities and is working to produce a fix. For more information, contact ORing directly.

CISA recommends users take defensive measures to minimize the risk of exploitation of this these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY
  • February 13, 2025: Initial Publication
CISA